This DTC indicates the vehicle control system disabled high-voltage components of the thermal management or air conditioning systems (e — Atto 3
This DTC indicates the vehicle control system disabled high-voltage components of the thermal management or air conditioning systems (e.g., electric compressor, PTC heater, battery chiller).
Trigger logic: When the air conditioning controller (ACU) or thermal management controller detects a high-voltage module status of "OK" or false "OK" (pseudo OK) via CAN bus message 244, it identifies a potential safety risk (such as a high-voltage interlock fault, over-temperature protection, or self-check failure with an incorrect status bit) and triggers the protection mechanism to cut off the high-voltage power supply.
Typical causes include loss of high-voltage interlock loop (HVIL) integrity, thermal management over-temperature protection, unsynchronized CAN communication data, or internal high-voltage component faults.
- 1High-voltage interlock loop (HVIL) wiring open circuit, terminal back-out, or poor contact, causing the system to incorrectly detect an abnormal high-voltage module connection.
- 2Thermal management system temperature sensor fault (battery pack coolant inlet temperature, motor coolant temperature, or air conditioning system temperature exceeds limits), triggering over-temperature protection logic.
- 3CAN bus communication fault, specifically loss, data errors, interference, or transmission delays of message 244 (air conditioning/thermal management status message).
- 4Electric compressor or PTC heater internal control board fault, causing the actual status to mismatch the OK status reported in the message (false OK).
- 5Air conditioning controller and BMS software version mismatch or control logic conflict, causing incorrect status judgment.
- 1Connect the VDS diagnostic tool, read the complete fault codes and data stream, and check for accompanying B2A6700 (compressor start failure), U-series communication faults, or temperature sensor fault codes.
- 2Check high-voltage interlock loop integrity: measure continuity at the HVIL pins on the low-voltage connectors of high-voltage components such as the electric compressor and PTC heater. Inspect the pins for push-out, oxidation, or water ingress.
- 3Read the thermal management data stream: Verify the battery pack coolant inlet/outlet temperatures, motor coolant temperature, compressor discharge temperature, and PTC temperature are within normal ranges (exclude abnormal values such as -40°C or 150°C).
- 4Check CAN communication: Measure CAN-H and CAN-L line resistance (standard 60Ω) and voltage (CAN-H 2.5-3.5V, CAN-L 1.5-2.5V) from the air conditioning controller (ACU) to the BMS. Verify normal transmission of message 244.
- 5Check high-voltage component status: measure the insulation resistance of the electric compressor three-phase high-voltage harness (>500MΩ), inspect the PTC heater high-voltage connector for burn marks, and verify the high-voltage component self-test program version.
- 6Perform software matching: Verify the ACU, BMS, and thermal management controller have the latest software versions. Update or synchronize configuration parameters if necessary.
- 7Clear the fault code, perform a high-voltage power-on test, and observe the high-voltage module status bit changes in the 244 message data stream to confirm fault resolution.
Qin Pro EV electric compressor HVIL pin retraction causing B2A6600
Qin Pro DM: PTC temperature sensor open circuit triggered high-voltage protection
Qin EV300: CAN Harness Wear Causes Message 244 Fault
Qin Pro EV battery cooler inlet temperature sensor drift