B2A6700

This DTC indicates the Electric A/C Compressor (EAC) fails to establish normal speed or pressure after multiple consecutive start attempts following a start command — Atto 3

Thermal Management System

This DTC indicates the Electric A/C Compressor (EAC) fails to establish normal speed or pressure after multiple consecutive start attempts following a start command.

The system logs a start failure fault.

The root cause is the compressor controller failing to provide a valid speed signal within the specified time (typically 2-3 seconds) or failing to build torque.

On plug-in hybrid (DM) models, an electric compressor failure prompts the system to start the engine to drive the mechanical compressor (Belt-driven Compressor) as a backup cooling solution, triggering DTC B2A6700.

This fault causes a complete loss of A/C cooling capacity, which is particularly severe in pure electric mode.

Additionally, because the BYD thermal management system couples the battery chiller (Chiller) with the A/C system, a prolonged fault can cause power battery thermal management failure, triggering power limits or even high-voltage interlock disconnection.

5
Cases Logged
5
Causes
  • 1Electric compressor high-voltage power supply fault: Causes include a blown compressor fuse in the high-voltage distribution box, poor contact in the high-voltage interlock loop (HVIL), burnt main negative/main positive contactors, or a damaged IPM module on the compressor internal motor drive board, preventing the compressor from receiving sufficient high-voltage DC power (typically 320V-750V).
  • 2Compressor mechanical seizure or motor fault: Internal scroll wear causing seizure, motor permanent magnet demagnetization, bearing seizure, or compressor oil deterioration causes excessive start-up torque, triggering controller overcurrent protection and resulting in start-up failure.
  • 3Low-voltage control communication fault: LIN bus or CAN bus communication interruption (between BMS, VCU, and compressor controller), abnormal wake-up signal, or Enable signal circuit open or shorted to ground, preventing the compressor controller from receiving the correct speed command.
  • 4Refrigerant pressure protective shutdown: Severely insufficient system refrigerant (leak) causes excessively low pressure on the low-pressure side, or excessive refrigerant/poor condenser heat dissipation causes excessively high pressure on the high-pressure side, triggering the pressure switch protection to prevent compressor startup.
  • 5Thermal Management System (TMS) controller or A/C controller software bug: Controller internal program logic error falsely reports a startup failure; or the algorithm threshold for deviation between the compressor target speed and actual control value is overly sensitive.
  • 1
    Diagnostic tool reading and freeze frame analysis: Use VDS2000 or Launch X431 to read all fault codes. Check for accompanying high-voltage interlock faults (P0A0D, P0A0E) or insulation faults (P1A00 series). Record the data stream for ambient temperature, battery SOC, compressor target speed, and actual speed at the time of the fault.
  • 2
    High-voltage safety check and insulation test: Disconnect the manual service disconnect (MSD). Wait 5 minutes for high-voltage discharge. Use a megohmmeter to measure the electric compressor high-voltage harness insulation resistance to ground (standard: >20MΩ). Inspect the high-voltage connectors for burn marks or backed-out pins. Measure high-voltage interlock circuit continuity.
  • 3
    Low-voltage circuit and communication check: Disconnect the compressor low-voltage connector and measure the pins: constant power (B+) should be 12V, ground (GND) resistance <0.1Ω, LIN line voltage approximately 9-11V (dynamic), and CAN-H/CAN-L voltage to ground approximately 2.5V. Use an oscilloscope to check the LIN bus waveform for distortion.
  • 4
    Refrigerant pressure and system sealing check: Connect a manifold gauge set and check the static pressure (R134a: approx. 0.6-0.8 MPa at 25°C). If the pressure is too low, evacuate the system using a vacuum pump, hold vacuum for 30 minutes, and locate leaks using an electronic leak detector (common leak points include the compressor shaft seal and high/low-pressure ports).
  • 5
    Compressor operation test and current monitoring: Restore the high-voltage connection, enter the scan tool actuator test mode, and gradually increase the compressor speed (1000rpm→3000rpm→6000rpm). Use a clamp meter to monitor the high-voltage current. Normal start-up current should be <15A and rise steadily. If the current is >40A, immediately cut the power. If the current exceeds 40A or oscillates, the compressor assembly is faulty.
  • 6
    Controller software update and replacement: If all above checks are normal, update the Thermal Management System (TMS) controller and compressor controller to the latest software version. If the fault persists, replace the electric compressor assembly (Note: After replacement, add the specified ND-OIL8 refrigerant oil or equivalent, and perform the standard refrigerant charge).
BYD DTC AI Analysis

Qin Pro DM: Backed-out HVIL pin causing intermittent no-start

Intermittent A/C not cooling with DTCs B2A6700 and P0A0D (high voltage interlock fault). Found a backed-out pin in the HVIL circuit of the electric compressor high voltage connector; contact failed over bumps. Re-crimped the pin and applied conductive grease. Fixed. Common on 2018–2019 Qin Pro models due to weak retaining clips in early high voltage connector designs.
BYD DTC AI Analysis

IGBT module inside Qin EV300 compressor burnt out, causing complete failure.

At 80,000 km, the AC failed completely. Scan tool showed DTC B2A6700. During actuator testing, the compressor did not respond and high-voltage side current read zero. Disassembled the compressor controller and found the internal IGBT power module burned out with visible burn marks on the driver board. Replaced the electric compressor assembly (part number: BC28-8103010) and refilled with 150 ml PAG 46 compressor oil and 450 g R134a refrigerant per specification. Fault resolved.
BYD DTC AI Analysis

Minor refrigerant leak triggered low-pressure protection, preventing startup

Poor AC cooling in high summer temperatures. DTC B2A6700 logged. Data stream showed compressor stopped within 2 seconds of engagement, low-side pressure dropping below 0.15 MPa. Vacuum hold test and fluorescent leak detection found a minor leak at the battery cooler (Chiller) connection. Repaired the leak, replaced the receiver drier, evacuated and recharged the system. Pressures normalized (low side 0.2–0.3 MPa, high side 1.4–1.6 MPa). Fault resolved.
BYD DTC AI Analysis

LIN bus interference caused compressor controller communication fault.

Aftermarket audio installation caused intermittent AC failure. Stored DTC B2A6700 with multiple LIN slave node communication faults. Found modified amplifier power wiring running parallel to the AC compressor LIN harness, causing electromagnetic interference. Re-routed wiring to separate power and signal lines (>30 cm apart) and installed a ferrite core filter on the compressor LIN line. Restored communication; fault has not reoccurred.
BYD DTC AI Analysis

Outdated thermal management controller software caused false fault detection.

The 2019 Qin Pro EV frequently set DTC B2A6700 in cold conditions (-5°C), but the compressor ran normally. Live data revealed the controller was overly sensitive to compressor speed overshoot. Upgraded the TMS controller software to the latest version (3.00.15 or above) via VDS2000, adjusting the startup failure threshold. The fault cleared. This is BYD's official software optimisation fix.
Common problems reported for Atto 3Atto 3 overview →
Data confidence: Official This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.