B110E09

This DTC indicates a functional failure of the temperature and humidity sensing module in the PM2 — Atto 8

Thermal Management System

This DTC indicates a functional failure of the temperature and humidity sensing module in the PM2.5 air quality rapid detection system.

This module integrates into the PM2.5 detector and monitors ambient air temperature and relative humidity in real time.

The system uses these readings to compensate and correct the light-scattering measurement data from the laser particulate sensor, as temperature and humidity changes significantly affect PM2.5 detection accuracy.

An abnormal analog signal or digital communication interruption causes this fault.

This prevents the air conditioning controller from obtaining accurate ambient temperature and humidity parameters, disabling the automatic air purification, negative ion generator linkage, and air quality display functions.

Although the system classifies this as a "severe" fault, it only affects comfort features and does not impact the powertrain or driving safety.

The vehicle can travel a short distance to a repair facility.

3
Cases Logged
5
Causes
  • 1Physical damage to the temperature and humidity sensor element: internal NTC thermistor open/short circuit or humidity-sensing capacitor failure, causing the output signal to fall outside the valid 0.5-4.5V range.
  • 2Poor wiring harness connector contact: The sensor plug located in the center of the dashboard or air conditioning intake housing is loose, has backed-out pins, or has oxidized terminals, causing intermittent signal interruption.
  • 3Power supply circuit fault: A damaged sensor 5V reference voltage module or excessive ground circuit resistance (>1Ω) causes unstable sensor operating voltage.
  • 4Condensation entering the module: The PM2.5 detector mounts near the air conditioning evaporator housing. Prolonged low-temperature environments produce condensation, corroding the temperature and humidity module PCB.
  • 5Sensor calibration data lost: Failure to perform the temperature and humidity sensor zero-point calibration after replacing the air conditioning controller or PM2.5 module causes the ECU to determine the signal is invalid.
  • 1
    Use the VDS2000/VDS3000 diagnostic tool to read all fault codes. Check for B110E09 and any accompanying B110A02 (CAN fault) or U-series communication faults, and record the ambient temperature value from the freeze frame data.
  • 2
    Remove the center dashboard trim and locate the PM2.5 sensor (usually behind the A/C control panel or inside the center air vent). Check if the wiring harness connector is loose. Measure the voltage between connector pin 1 (power) and pin 3 (ground). Standard value: 5V ± 0.25V.
  • 3
    Disconnect the connector and measure the resistance to ground at the temperature and humidity sensor signal pin (2#): at 25°C, the temperature sensor resistance should be 2-3 kΩ (NTC characteristic), and the humidity sensor resistance should be 200 Ω-20 kΩ, varying with humidity. If the resistance is infinite or close to 0 Ω, the sensor itself is damaged.
  • 4
    If the power supply and sensor are normal, check wiring harness continuity: the signal wire resistance from the PM2.5 sensor connector to the A/C controller (or BMS/thermal management controller, depending on vehicle configuration) must be <1 Ω, and the insulation resistance to body ground must be >10 MΩ.
  • 5
    Replace the PM2.5 sensor assembly (the temperature and humidity module is generally unavailable as a separate spare part). After installation, calibrate the sensor: use the diagnostic tool to access 'Air Conditioning System - Special Functions - PM2.5 Sensor Calibration', follow the prompts to complete the temperature and humidity zero-point calibration, clear the fault code, and verify with a road test.
BYD DTC AI AnalysisFrom Chinese market (translated)

BYD Qin Pro DM instrument cluster intermittently displays 'Air Quality Detection Fault'

After parking overnight, started the vehicle. The dashboard indicated an air quality system fault, and the air conditioning auto mode could not activate the purification function. Retrieved current fault code B110E09 using a diagnostic tool. Inspection found the PM2.5 sensor above the centre console; its wiring harness plug retaining clip had broken, causing the connector to work loose. When the vehicle vibrated during driving, the signal would cut out. Resecured the plug and reinforced it with cable ties. Cleared the fault codes and observed the temperature and humidity data displayed normally. Fault resolved.
BYD DTC AI AnalysisFrom Chinese market (translated)

Qin Pro EV PM2.5 function inoperative after air conditioning repair

After replacing the evaporator assembly at the dealership, I noticed the centre screen no longer showed the outside PM2.5 value. Retrieved DTC B110E09. Inspection found that during the dashboard removal, a tool had touched the temperature and humidity sensor probe on the PM2.5 detector, physically damaging the internal humidity-sensitive element. Measured the sensor signal line voltage: constant 4.9 V (normally it should fluctuate between 1–4 V with temperature and humidity changes). Replaced the PM2.5 detector assembly, then performed the 'Air Quality Sensor Learning' function using the diagnostic tool. Live data showed 25 °C and 60% humidity; function returned to normal.
BYD DTC AI AnalysisFrom Chinese market (translated)

Prolonged exposure to high humidity caused sensor corrosion

Vehicle used in a coastal city. After 2 years, DTC B110E09 appeared. Removed and inspected the PM2.5 sensor and found obvious salt spray corrosion on the internal circuit board, with oxidised solder joints on the temperature and humidity sensor. The cause was prolonged high-load operation of the air conditioning system combined with coastal humidity, resulting in moisture ingress to the sensor module. After cleaning the corrosion from the circuit board, the fault cleared temporarily, but returned after one week. Replaced the PM2.5 sensor and applied conductive anti-corrosion grease to the wiring harness connector, permanently fixing the fault.
Data confidence: Official This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself. Sources: [1]