This DTC indicates the Electric A/C Compressor (EAC) fails to establish normal speed or pressure after multiple consecutive start attempts following a start command — Atto 8
This DTC indicates the Electric A/C Compressor (EAC) fails to establish normal speed or pressure after multiple consecutive start attempts following a start command.
The system logs a start failure fault.
The root cause is the compressor controller failing to provide a valid speed signal within the specified time (typically 2-3 seconds) or failing to build torque.
On plug-in hybrid (DM) models, an electric compressor failure prompts the system to start the engine to drive the mechanical compressor (Belt-driven Compressor) as a backup cooling solution, triggering DTC B2A6700.
This fault causes a complete loss of A/C cooling capacity, which is particularly severe in pure electric mode.
Additionally, because the BYD thermal management system couples the battery chiller (Chiller) with the A/C system, a prolonged fault can cause power battery thermal management failure, triggering power limits or even high-voltage interlock disconnection.
- 1Electric compressor high-voltage power supply fault: Causes include a blown compressor fuse in the high-voltage distribution box, poor contact in the high-voltage interlock loop (HVIL), burnt main negative/main positive contactors, or a damaged IPM module on the compressor's internal motor drive board, preventing the compressor from receiving sufficient high-voltage DC power (typically 320V-750V).
- 2Compressor mechanical seizure or motor fault: Internal scroll plate wear and seizure, motor permanent magnet demagnetization, bearing seizure, or degraded refrigerant oil causes excessive start-up torque, which triggers controller overcurrent protection and causes start-up failure.
- 3Low-voltage control communication fault: LIN bus or CAN bus communication interruption (between the BMS, VCU, and compressor controller), abnormal wake-up signal, or enable signal circuit open or short to ground, preventing the compressor controller from receiving the correct speed command.
- 4Refrigerant pressure protective shutdown: Severe system refrigerant shortage (leakage) causes excessively low pressure on the low-pressure side, or excessive refrigerant/poor condenser heat dissipation causes excessively high pressure on the high-pressure side, triggering pressure switch protection to prevent compressor startup.
- 5Thermal Management System (TMS) controller or air conditioning controller software bug: an internal controller program logic error falsely reports a startup failure; or the algorithm threshold for deviation between the compressor target speed and actual control value is too sensitive.
- 1Diagnostic tool reading and freeze frame analysis: Use VDS2000 or Launch X431 to read all fault codes. Check for accompanying high-voltage interlock (P0A0D, P0A0E) or insulation (P1A00 series) faults. Record the ambient temperature, battery SOC, compressor target speed, and actual speed data streams at the time of the fault.
- 2High-voltage safety check and insulation test: Disconnect the manual service disconnect (MSD) and wait 5 minutes for high-voltage discharge. Use a megohmmeter to measure the electric compressor high-voltage harness insulation resistance to ground (standard >20MΩ). Inspect the high-voltage connectors for burning or backed-out pins. Measure the high-voltage interlock circuit continuity.
- 3Low-voltage circuit and communication check: Disconnect the compressor low-voltage connector and measure the pins: constant power (B+) should be 12V, ground (GND) <0.1Ω, LIN line voltage approximately 9-11V (dynamic), and CAN-H/CAN-L voltage to ground approximately 2.5V. Use an oscilloscope to check the LIN bus waveform for distortion.
- 4Refrigerant pressure and system sealing check: Connect a manifold gauge set and check the static pressure (R134a at approx. 25°C: 0.6-0.8 MPa). If the pressure is too low, evacuate the system using a vacuum pump and hold the vacuum for 30 minutes. Use an electronic leak detector to locate leaks (commonly found at the compressor shaft seal and high/low-pressure ports).
- 5Compressor operation test and current monitoring: Restore the high-voltage connection. Enter the scan tool actuator test mode and gradually increase the compressor speed (1000rpm→3000rpm→6000rpm). Monitor the high-voltage current using a clamp meter. Normal start-up current must be <15A and rise steadily. If the current is >40A, immediately cut the power. If the current is >40A or oscillates, the compressor assembly is faulty.
- 6Controller software update and replacement: If all above checks are normal, update the Thermal Management Controller (TMS) and compressor controller to the latest software version. If the fault persists, replace the electric compressor assembly (Note: After replacement, add the specified ND-OIL8 refrigerant oil or equivalent, and charge the standard amount of refrigerant).
Qin Pro DM: Backed-out HVIL pin causing intermittent no-start
IGBT module inside Qin EV300 compressor burnt out, causing complete failure.
Minor refrigerant leak triggered low-pressure protection, preventing startup
LIN bus interference caused compressor controller communication fault.
Outdated thermal management controller software caused false fault detection.