DTC U014987 indicates a communication link interruption between the battery thermal management controller (usually integrated into the Battery Management System (BMS) or a separate thermal management control unit) and the battery thermal circuit electric coolant pump — Atto 8
DTC U014987 indicates a communication link interruption between the battery thermal management controller (usually integrated into the Battery Management System (BMS) or a separate thermal management control unit) and the battery thermal circuit electric coolant pump.
This pump drives battery coolant circulation and typically uses LIN bus (CAN bus on some models) for digital communication.
The controller triggers this fault when it fails to receive pump status feedback signals (such as speed, temperature, or fault status) within a specified period (generally 100-200ms), or when it cannot send control commands (such as target speed requests).
This fault forces the battery thermal management system into open-loop control or degraded mode, limiting fast-charging power and power output.
Extreme cases may trigger battery high-temperature protection.
- 1Electronic water pump power supply circuit fault: Includes a blown 15A/20A fuse, an open power supply circuit, or a poor connection, preventing the water pump control module from operating properly.
- 2LIN/CAN communication circuit fault: short to ground, short to power, open circuit, or excessive contact resistance (>5Ω). Faults typically occur at harness bends near the battery pack or the firewall wiring pass-through.
- 3Electric water pump assembly fault: damaged internal brushless motor drive circuit, seized motor rotor, damaged LIN transceiver chip, or internal overheat protection activated.
- 4Connector issue: Water ingress, oxidation, terminal pin back-out, or locking mechanism failure at the battery pack low-voltage connector (usually located at the front of the battery pack near the BJB or service disconnect switch).
- 5Thermal management controller or gateway fault: damaged controller internal communication chip, software version defect, incorrect gateway routing table configuration, or abnormal terminating resistor.
- 1Use the VDS diagnostic tool to read all fault codes. Confirm if U014987 is a current fault, check for accompanying communication fault codes, and view the freeze frame data (record parameters such as battery temperature and requested coolant pump speed at the time of the fault).
- 2Visually inspect the electric water pump condition and installation. Verify there is no coolant leakage, abnormal noise, or mechanical damage to the wiring harness. Specifically inspect the low-voltage connector at the front of the battery pack to verify it is fully locked and free of water ingress.
- 3Disconnect the electric water pump connector. Measure the voltage between the constant power pin (usually B+) and body ground; it should be 12V±0.5V. Measure the resistance between the ground wire pin and body ground; it should be <1Ω. Check if the fuse is blown.
- 4Measure communication line voltages and waveforms (LIN line normally approx. 9-11 V, CAN-H approx. 2.6-2.8 V, CAN-L approx. 2.2-2.4 V). Use an oscilloscope to check for signal distortion. Measure circuit resistance to confirm no open or short circuits.
- 5Check the connector pins for green copper corrosion, backed-out terminals, or enlarged pin holes. Use the dedicated tool to repair the pins. Clean the pins and apply electrical contact protectant. Verify the connector waterproof sealing ring is intact.
- 6Perform the actuator test: Use the diagnostic tool to drive the water pump and listen for pump operation. If the tool cannot drive the pump, swap with a known-good electric water pump to verify if the fault follows the component.
- 7Check the thermal management controller: Measure wiring harness continuity from the controller to the water pump (resistance <1Ω). Check the controller software version and update to the latest version. Replace the thermal management controller or gateway module if necessary.
Poor contact in the front-end wiring harness of the Qin EV battery pack caused an intermittent communication fault.
Loose ground point on Qin EV thermal management water pump caused communication loss
e5 water pump power fuse holder burned, causing communication fault
Burnt thermal management relay contacts caused water pump communication failure on Qin EV
Seal 06 thermal management controller software defect caused water pump communication error