U025387 is a U-category network communication DTC — Atto 8
U025387 is a U-category network communication DTC.
It indicates a CAN bus communication interruption between the Vehicle Control Unit (VCU) or thermal management controller and the Electric Air Conditioning Compressor Controller (ACCM).
This fault indicates the main control unit failed to receive valid messages (such as status, speed, and fault data) from the compressor controller within the predetermined cycle (typically 100ms-500ms).
This represents a control link communication loss rather than a mechanical failure of the compressor itself.
The fault completely disables the air conditioning system (no cooling/heating).
This failure subsequently triggers battery thermal management degradation (limiting fast charge power and affecting battery life) and causes insufficient motor cooling (triggering high-temperature protection and power reduction).
Severe cases restrict EV functions or prevent the vehicle from starting.
- 1Loose front compartment wiring harness connector, backed-out terminals, or poor contact: High temperatures (such as sun exposure) cause thermal expansion and contraction, forcing connector terminals (such as B28 and the front compartment wiring harness mating connector) to back out, oxidize, or develop poor contact, resulting in intermittent communication loss.
- 2Electric compressor controller power supply or ground fault: blown fuse, relay failure, open power supply circuit, or loose ground point, causing controller power loss and communication failure.
- 3CAN network physical layer fault: short or open circuit in powertrain CAN or thermal management sub-network wiring; abnormal terminating resistance (normal: approx. 60Ω; abnormal: 120Ω or open circuit); electromagnetic interference causing signal distortion.
- 4Compressor controller internal fault: controller software crash, hardware damage (e.g., burnt internal power supply chip), or waterproof seal failure causing internal water ingress and circuit board corrosion.
- 5Compressor body insulation fault: Insulation resistance between the high-voltage section and ground decreases (<2MΩ), triggering a protective controller power-off or causing the BMS to disconnect high voltage, indirectly interrupting communication.
- 1Fault confirmation and data recording: Use the VDS2000/3000 diagnostic tool to read all fault codes. Confirm whether U025387 is a current fault (Active) or a history fault (History). Record the freeze frame data (ambient temperature, battery temperature, vehicle speed, etc.). Clear the fault codes and road test the vehicle to confirm if the fault reoccurs.
- 2Low-voltage wiring harness and connector inspection: Disconnect the battery negative terminal. Check the electric compressor low-voltage wiring harness connectors (focusing on the front compartment harness interface connector and right domain controller Port E). Verify pins are not backed out, bent, corroded, or burnt. Measure voltage at the power supply pins (+B, IG) (12V±0.5V) and resistance at the ground pins (<1Ω).
- 3CAN network physical layer measurement: Use an oscilloscope or multimeter to measure CAN-H (2.5-3.5V) and CAN-L (1.5-2.5V) voltage to ground. Disconnect the battery and measure the CAN termination resistance (standard value is approximately 60Ω; a 120Ω reading indicates a missing termination resistor on one side; 0Ω indicates a short circuit). In high-temperature environments, monitor the resistance value for temperature drift.
- 4High-voltage insulation test: Use a 1000V megohmmeter to measure the insulation resistance between the compressor high-voltage input terminal and body ground. Standard: ≥20MΩ (some models require ≥2MΩ). Low resistance indicates internal compressor leakage (scroll plate seal failure or motor winding insulation damage).
- 5Controller software diagnosis and reflashing: Check the VCU, integrated body controller (B2), and compressor controller software versions. Confirm they are the latest versions and check for version compatibility issues. Reflash or program and match the controllers. If necessary, perform 'non-sleep data collection' to analyze the message loss pattern.
- 6Component replacement verification: Swap the faulty vehicle's compressor controller with one from a known good vehicle, or swap the front compartment wiring harness to verify if the fault transfers. If diagnostics confirm a faulty compressor assembly, replace the assembly and add the specified POE refrigerant oil (such as SP-A2). Never mix with mineral oil.
Qin PLUS DM-i won't start after high-temperature exposure (wiring harness connector pin backed out)
Tang DM EV Function Limited (Module Version Mismatch)
Qin Pro DM A/C compressor insulation failure caused communication interruption
Qin EV: AC Suddenly Failed While Driving (CAN Network Resistance Drift)
Qin PLUS EV communication fault after compressor replacement (software not configured)