This DTC indicates the air conditioning system control unit or a thermal management-related module detects its operating supply voltage exceeds the 16V threshold (BYD low-voltage system rated voltage: 12V; normal operating range: 9–16V) — Qin Plus
This DTC indicates the air conditioning system control unit or a thermal management-related module detects its operating supply voltage exceeds the 16V threshold (BYD low-voltage system rated voltage: 12V; normal operating range: 9–16V).
This is an overvoltage protection fault.
When the module detects an abnormal rise in supply voltage, it stores this DTC and may enter protection mode, limiting air conditioning or thermal management functions to prevent electronic component damage.
Overvoltage typically stems from abnormal output from the low-voltage charging system (DC-DC converter), alternator voltage regulator failure (hybrid models), or abnormal power supply circuit impedance.
Prolonged overvoltage may burn out the control module internal circuits or damage the compressor driver.
- 1DC-DC converter fault: The internal voltage regulation circuit of the high-voltage to low-voltage DC-DC module fails, causing the output voltage to exceed 16V. This is the most common cause.
- 2Severe aging of the low-voltage battery: Increased internal resistance or plate sulfation prevents the battery from accepting normal current during charging, causing terminal voltage to rise abnormally.
- 3Generator voltage regulator fault (hybrid models): ISG motor or generator controller failure causing unregulated output voltage.
- 4Poor power wiring harness contact: A loose or oxidized positive harness connector, or poor ground point contact, changes circuit impedance and causes the module to detect a false high voltage.
- 5Air conditioning control module sampling circuit fault: A faulty internal A/D conversion circuit or voltage divider resistor triggers a false overvoltage fault.
- 1Use a high-precision multimeter to measure the low-voltage battery static voltage and dynamic voltage (when applying the air conditioning load). Confirm whether the actual voltage exceeds 16V to rule out a false fault.
- 2Connect the VDS diagnostic tool and read the data stream. Check the 'System Voltage' data stream in the air conditioning module or thermal management module to confirm whether the overvoltage is continuous or intermittent.
- 3Check the DC-DC converter output voltage: With the vehicle in READY mode, measure the voltage at the DC-DC output terminal. Normal voltage is 13.8-14.5V. If the voltage exceeds 16V, replace the DC-DC assembly.
- 4Check low-voltage battery health: Use a battery tester to measure the CCA value and internal resistance. If internal resistance exceeds 5mΩ or capacity is below 50%, replace the 12V battery.
- 5Check power supply circuit integrity: Check the air conditioning control module constant power (B+), ignition power (IG), and ground (GND) connectors. Inspect the wiring harness from the instrument panel power distribution box to the air conditioning module for oxidation or poor connections.
- 6Check relevant fuses and relays: Verify the air conditioning system fuses (typically located in the dashboard fuse box and engine compartment fuse box) are securely seated and show no signs of burning.
- 7If the hardware inspection reveals no abnormalities, upgrade or reflash the air conditioning control module software to rule out false faults resulting from software calibration.
- 8If all above checks are normal, replace the air conditioning control module or thermal management control unit and perform coding.
Qin Pro DM: DC-DC converter abnormal output caused air conditioning failure
Battery aging causes intermittent overvoltage fault in Qin EV300
Poor contact in the dashboard power distribution box caused the A/C module to detect overvoltage.
Reflashed the air conditioning controller to resolve a software false alarm.