DTC B1670 indicates an abnormally low-resistance connection (short to ground) between the right Side Impact Sensor (SIS) signal circuit and body ground (GND) — Qin Plus
DTC B1670 indicates an abnormally low-resistance connection (short to ground) between the right Side Impact Sensor (SIS) signal circuit and body ground (GND).
Electrically, this typically indicates damaged signal wire insulation contacting body metal, an internal connector short, or a sensor internal integrated circuit fault shorting the signal output terminal to the housing.
This fault causes the Airbag Control Unit (ACU) to continuously receive a false 'crash trigger' signal (voltage near 0V) or completely lose sensor communication.
Consequently, the ACU enters fail-safe mode, disabling the right airbag and side curtain airbag to prevent accidental deployment.
Additionally, if the system identifies the short circuit as a continuous crash signal on certain models, it may trigger unintended airbag deployment.
This fault constitutes a severe safety hazard and requires immediate repair.
- 1Right side impact sensor wiring harness wear: During long-term vehicle use, the sensor wiring harness located in the right B-pillar or sill trim rubs against body metal edges or retaining clips. This damages the insulation layer and shorts the copper core to body ground.
- 2Connector water ingress or corrosion: Driving through water, a blocked sunroof drain tube, or improper car washing causes moisture to enter the right crash sensor connector (usually located below the B-pillar or under the seat), resulting in a short circuit between pins or to ground.
- 3Internal sensor fault: A damaged piezoelectric element or signal processing circuit inside the crash sensor causes the signal output terminal to short to the sensor housing (ground).
- 4Improper accident repair: After a right-side collision, incorrect routing or inadequate securing of the wiring harness during repair, or an electrical connector mismatch caused by non-genuine parts, causes a short circuit.
- 5SRS control unit (ACU) interface fault: In very rare cases, damaged components in the ACU internal right-side sensor signal receiving circuit cause a false short-to-ground detection.
- 1Safety preparation: Disconnect the battery negative terminal and wait at least 3 minutes to discharge the airbag system energy storage capacitor and prevent accidental airbag deployment during repair.
- 2Fault confirmation and freeze frame recording: Use the BYD VDS diagnostic tool to read the DTC B1670 status (current/history), record the freeze frame data (vehicle speed at time of fault, timestamp, sensor voltage value), and confirm the specific right-side sensor location (front/center/rear).
- 3Visual inspection: Remove the right B-pillar trim, sill trim, or seat (depending on vehicle configuration). Check the crash sensor for physical damage, the wiring harness for obvious crushing, cuts, or abrasion, and the connector for water ingress, oxidation, or deformed pins.
- 4Electrical measurement verification: Disconnect the right side impact sensor connector. Use a multimeter to measure the resistance between the signal wire (usually the positive wire) and body ground. Normal resistance is >1 MΩ (open circuit). A reading of 0-5 Ω confirms a short to ground. Simultaneously measure the resistance between the sensor output terminal and the housing to check for an internal short circuit.
- 5Wiring harness sectional inspection: If the sensor is normal, strip the wiring harness sheath in sections from the sensor toward the ACU. Closely inspect body pass-throughs (firewall, B-pillar), harness clip points, and bent sections to locate damage.
- 6Repair or replace: If the wiring harness is damaged, rewrap it with heat-shrink tubing or insulating tape, and reroute the harness to prevent further chafing. If the sensor has an internal short circuit, replace it with a genuine right side impact sensor (Note: Some models require sensor calibration or coding).
- 7System verification: Restore all connections and reconnect the battery. Use VDS to clear the fault code. Perform the SRS system self-diagnosis procedure and confirm B1670 does not return. Finally, perform a road test or simulated vibration test to verify complete fault resolution.
BYD Song MAX B1670 – Right B-pillar wiring harness chafed, shorting to ground (Reference: similar SRS harness fault B2290)
BYD Qin Pro B1670 side impact sensor connector water ingress and corrosion (reference case: similar connector fault B2692)
BYD Tang DM B1670 Side Impact Sensor Internal Circuit Fault (Reference case: similar sensor body fault B00C8)