This DTC indicates a fault in the drive circuit of the HVAC Recirculation Air Door Actuator motor — Qin Plus
This DTC indicates a fault in the drive circuit of the HVAC Recirculation Air Door Actuator motor.
Specifically, a "short to ground" indicates insulation failure between the motor supply line (typically the PWM control line or power line) and the vehicle body ground (GND), causing abnormal current leakage.
An "open circuit" indicates a broken internal motor coil, a loose connector, or a severed wiring harness.
This motor switches the HVAC air door between fresh air and recirculation modes.
A fault prevents mode switching or causes the door to stick in a fixed position, reducing cabin temperature control efficiency.
In extreme cases, this reduces battery thermal management performance (e.g., preventing effective heat dissipation via fresh air mode).
Therefore, the system classifies this as a severe fault.
- 1Recirculation air flap actuator motor internal coil burnt out or short-circuited: Prolonged motor jamming or overload damages the coil insulation, resulting in a short to ground or internal open circuit.
- 2Wiring harness and connector fault: Water ingress or poor sealing causes pin corrosion or oxidation at the wiring harness connector near the HVAC unit (usually behind the glovebox or firewall), or vehicle vibration loosens the male and female terminals.
- 3Mechanical jamming causes motor damage: Foreign matter (such as leaves or accumulated dust) jams the air flap mechanism, or the linkage deforms. This causes excessive motor stall current, eventually burning out the drive circuit or motor winding.
- 4Air conditioning controller (HVAC ECU) internal fault: Damage to the internal H-bridge drive circuit or MOSFET causes an abnormal output signal (such as a short to ground), triggering a false fault.
- 5Wiring harness worn or damaged: An improperly secured wiring harness in the engine compartment or instrument panel rubs against metal body edges, damaging the insulation and causing a short to ground.
- 1Diagnostic confirmation: Use the BYD VDS diagnostic tool to read all DTCs. Confirm only B2A4B14 or related fault codes are present. Record freeze frame data (such as motor duty cycle and position feedback value at the time of the fault). Clear the fault codes, operate the fresh air/recirculation switch, and verify if the fault reoccurs.
- 2Visual and connector inspection: Remove the glove box or front passenger lower trim panel and locate the recirculation flap actuator (usually marked 'REC' or 'Intake'). Check the connector for looseness, backed-out pins, or green/white corrosion. Measure the connector terminal resistance to ground to check for a short circuit.
- 3Actuator unit inspection: Disconnect the connector and use a multimeter to measure the resistance between the two motor terminals (normal range is typically 30-80Ω; refer to the vehicle repair manual for specific values). A resistance of 0Ω indicates a short circuit; infinite resistance indicates an open circuit. Also, manually move the air flap blade to confirm the mechanical mechanism operates without binding or abnormal noise.
- 4Harness continuity and insulation test: Measure harness continuity (power wire, ground wire, signal wire) from the actuator connector along the harness toward the air conditioning controller. Use a megohmmeter or a multimeter on the high-resistance setting to measure the insulation resistance of each wire to ground. Resistance must be greater than 1MΩ. Inspect harness bend points passing through the firewall and hinges.
- 5Controller output check: Connect the diagnostic tool and perform the Actuation Test. Observe the PWM output waveform and voltage from the air conditioning controller to the recirculation motor. If the controller output is normal but the motor does not operate, replace the actuator. If the controller has no output or the output is shorted to ground, repair or replace the air conditioning controller.
- 6Component replacement and repair: Replace the recirculation air flap actuator motor (Note: some models require replacing the complete air flap housing assembly) or repair the damaged wiring harness (seal with heat-shrink tubing and restore original wrapping). If the flap mechanism binds, clear foreign matter and apply specified grease.
- 7Calibration and Verification: After completing the repair, use VDS to execute the 'Door Motor Calibration' procedure to teach the controller the flap limit positions. Operate the recirculation/fresh air switch and confirm the flap moves smoothly without abnormal noise. Read the data stream to confirm the position feedback value changes according to the command (recirculation is typically 0-20%, fresh air is 80-100%). Perform a road test to verify the fault code does not recur.
Song MAX recirculation door jammed, motor burned out
Qin Pro EV HVAC unit wiring harness chafed, shorted to ground
Qin EV300 Actuator Internal Open Circuit Fault