C001500

DTC C001500 indicates the IPB (Integrated Power Brake) ECU detects a circuit fault while actuating the right front wheel outlet valve (RF Outlet Valve, a Normally Closed Valve) — Qin Plus

Braking System

DTC C001500 indicates the IPB (Integrated Power Brake) ECU detects a circuit fault while actuating the right front wheel outlet valve (RF Outlet Valve, a Normally Closed Valve).

This solenoid valve returns brake fluid from the right front wheel cylinder to the reservoir or master cylinder during the ABS/ESC pressure release phase, enabling precise brake force control.

Root causes include an open or short circuit in the solenoid coil, a damaged ECU on-board driver chip (MOSFET/ASIC), abnormal current feedback (e.g., mechanical valve sticking causing a current over-limit), or a wiring harness fault.

This fault prevents the right front wheel from achieving accurate pressure build-up, hold, and release cycles, and disables ABS/ESC functions.

In extreme cases, it causes right front wheel brake drag and uneven brake force distribution, severely compromising driving safety.

3
Cases Logged
5
Causes
  • 1Open circuit, inter-turn short circuit, or short to housing in the right front outlet valve solenoid coil inside the IPB assembly
  • 2IPB control unit (ECU) onboard solenoid valve drive circuit damaged (e.g., L9305 chip or high-side/low-side driver transistor breakdown)
  • 3Oxidation, terminal back-out, corrosion from water ingress, or poor contact at the corresponding pins of the IPB wiring harness connector (usually a 32-pin or 48-pin plug)
  • 4Severely contaminated brake fluid (excessive water content or impurities) causes the solenoid valve spool to stick, resulting in the drive current exceeding the calibrated threshold.
  • 5IPB power supply system fault (battery voltage below 9V or above 16V, or excessive ground resistance) causing false protection of the drive circuit.
  • 1
    Diagnostic tool reading: Use a BYD VDS or Launch X-431 diagnostic tool to read the complete DTC, freeze frame data, and fault occurrence counter (FDC). Record key data at the time of the fault, including vehicle speed, wheel speed, and brake pedal travel.
  • 2
    Visual inspection: Inspect the IPB assembly (located on the left side of the front bulkhead in the engine compartment) for impact deformation and brake fluid leakage. Specifically check wiring harness connectors X1 and X2 for looseness, failed locking tabs, damaged sealing rings, water stains, or corrosion.
  • 3
    Solenoid valve resistance measurement: Disconnect the IPB connector. Use a multimeter to measure the resistance between the two terminals of the right front outlet valve solenoid (standard value: approx. 2.0-10.0Ω at 20°C; refer to the vehicle repair manual for specifics). If the resistance is infinite (open circuit) or close to 0Ω (short circuit), the internal coil is faulty.
  • 4
    Wiring harness continuity test: Measure continuity between the valve body side pin of the IPB connector and the corresponding ECU side pin. Check for open circuits, shorts to power, or shorts to ground. Also measure the circuit insulation resistance; it must be greater than 10MΩ.
  • 5
    Power supply and ground check: Use an oscilloscope or multimeter to measure the voltage at the IPB power supply pins (constant B+, ignition IG1) and the voltage drop at the ground pins. Verify the voltage is 12-14V with the engine running and the ground voltage drop is less than 0.1V.
  • 6
    Actuation test verification: Connect the diagnostic tool and perform the “Solenoid Valve Actuation Test” or “Hydraulic Unit Function Test”. Listen for a crisp click from the right front outlet valve. If no sound occurs or the diagnostic tool reports a drive failure, diagnose a mechanically stuck valve body or an ECU drive circuit fault.
  • 7
    Part replacement: After confirming the fault, replace the IPB electro-hydraulic module assembly (Song PLUS DM-i spare part number example: 6A-3505010-XX). Recover brake fluid from the old module before replacement to prevent contamination.
  • 8
    System calibration and bleeding: After replacement, use the diagnostic tool to perform the "Brake Line Automatic Bleeding" procedure (requires continuously pumping the brake pedal), then perform "ESC Sensor Calibration", "Longitudinal Acceleration Sensor Calibration", and "Steering Angle Sensor Calibration".
  • 9
    Road test verification: Clear all fault codes. Perform a static brake pedal test. Confirm there are no leaks, then perform low-speed (20km/h) and high-speed (above 60km/h) emergency braking tests. Verify the ABS operates normally, there is no abnormal brake drag, and the fault code does not recur.
BYD DTC AI Analysis

BYD Song PLUS DM-i ABS/ESP warning, right front outlet valve driver circuit fault

While driving, the ABS and ESC warning lights came on. Scanned DTC C001500 (Right Front Outlet Valve Drive Fault). Checked IPB wiring harness connections; normal. Measured internal solenoid resistance; open circuit. Confirmed open circuit in right front normally closed valve coil inside IPB assembly. Replaced IPB electro-hydraulic module assembly. Performed sensor calibration. System returned to normal.
Original source ↗
BYD DTC AI Analysis

Dashboard ABS warning light stays on. Diagnosis: right front outlet valve circuit fault.

After starting the vehicle, the ABS warning light remained illuminated and the system failed its self-test. The scan tool retrieved DTC C0015 (right front outlet valve fault). Inspection revealed an internal circuit fault in the right front outlet valve within the ABS Hydraulic Control Unit (HCU); the solenoid valve would not actuate. The external wiring harness showed no damage, confirming an internal HCU failure. Replacing the ABS Hydraulic Control Unit assembly resolved the fault.
Original source ↗
BYD DTC AI Analysis

ESC warning light illuminated while driving; faulty normally closed valve in right front wheel caused abnormal braking.

While driving, the ABS and ESC warning lights suddenly illuminated and the driver felt abnormal brake pedal travel. The scan tool displayed C0015-00 (right front normally closed valve fault). Testing revealed the right front outlet valve resistance fell outside the standard range (2-10 ohms) and the valve produced no operating sound during the actuator test. Confirmed an internal IPB solenoid valve fault. Replaced the IPB assembly, bled the brakes and calibrated the ESC. The fault codes cleared and the road test returned normal results.
Original source ↗
Data confidence: Official This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.