This DTC indicates the air conditioning system control unit or a thermal management-related module detects its operating supply voltage exceeds the 16V threshold (BYD low-voltage system rated voltage: 12V; normal operating range: 9–16V) — Qin Plus
This DTC indicates the air conditioning system control unit or a thermal management-related module detects its operating supply voltage exceeds the 16V threshold (BYD low-voltage system rated voltage: 12V; normal operating range: 9–16V).
This is an overvoltage protection fault.
When the module detects an abnormal rise in supply voltage, it stores this DTC and may enter protection mode, limiting air conditioning or thermal management functions to prevent electronic component damage.
Overvoltage typically stems from abnormal output from the low-voltage charging system (DC-DC converter), alternator voltage regulator failure (hybrid models), or abnormal power supply circuit impedance.
Prolonged overvoltage may burn out the control module internal circuits or damage the compressor driver.
Qin Pro DM: DC-DC converter abnormal output caused air conditioning failure
Battery aging causes intermittent overvoltage fault in Qin EV300
Poor contact in the dashboard power distribution box caused the A/C module to detect overvoltage.
Reflashed the air conditioning controller to resolve a software false alarm.