B2AB149

This DTC indicates a phase loss in the internal three-phase permanent magnet synchronous motor of the electric A/C compressor (E-Compressor) — Seal 6 EV

Thermal Management System

This DTC indicates a phase loss in the internal three-phase permanent magnet synchronous motor of the electric A/C compressor (E-Compressor).

When the compressor controller (inverter) supplies power to the motor U/V/W three-phase windings, it detects a loss of at least one phase current or a voltage drop exceeding the threshold.

Open windings, open high-voltage harnesses, or damaged IGBT power modules typically cause this condition.

This fault prevents the compressor from generating effective torque and forces it to stop, which disables the A/C cooling and heating functions and triggers the thermal management system derating protection.

In vehicles like the BYD Qin EV, battery cooling relies on the A/C refrigerant circuit; therefore, this fault may indirectly raise the battery pack temperature and limit charge and discharge power.

4
Cases Logged
BYD DTC AI Analysis

Burnt high-voltage plug on Qin EV compressor causing intermittent phase loss

Intermittent AC cooling failure. Read DTC B2AB149. Inspection found visible burning and blackening on U-phase terminal of compressor high-voltage connector. Measured U-phase contact resistance at 12Ω (normal <0.1Ω). Poor contact caused arcing under high current, gradually burning the terminal. Replaced compressor high-voltage wiring harness assembly (including connector) and applied conductive paste. Issue resolved.
BYD DTC AI Analysis

Damaged electric compressor IGBT module triggered phase loss protection

Total AC failure with DTCs B2AB149 and B2AB2-49. Removed and inspected the compressor controller; found the V-phase lower bridge arm IGBT in the IPM module shorted. Compressor windings measured normal. Isolated to controller power device quality defect. BYD does not offer standalone controller repair, so replaced the electric compressor assembly. System restored to normal with balanced three-phase current.
BYD DTC AI Analysis

Refrigerant leak caused compressor overheating and phase loss

Owner reported AC cooling gradually weakened until complete failure. DTC B2AB149 stored. Found severe refrigerant leak (pressure <0.1MPa). Compressor ran dry for an extended period without oil or refrigerant, overheating the motor windings and damaging insulation until the V-phase winding opened. Replaced compressor, repaired condenser leak, and charged standard refrigerant (450g R410a) and refrigeration oil. Fault resolved.
BYD DTC AI Analysis

High-voltage distribution box relay contacts burned

AC cut in and out. DTC B2AB149 intermittent. Compressor relay contacts inside HV distribution box severely burned, causing W-phase power to drop out. Relay coil tested normal, but contact resistance fluctuated with vibration. Replaced distribution box relay (or complete assembly). Fault code cleared and did not return; three-phase voltage balanced and stable.
Data confidence: Community This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.