DTC U2ABB17 indicates the electric compressor controller (PCU) detects the input DC high voltage exceeds the permitted operating threshold (typically 110%-120% of the rated voltage) — Atto 3
DTC U2ABB17 indicates the electric compressor controller (PCU) detects the input DC high voltage exceeds the permitted operating threshold (typically 110%-120% of the rated voltage).
For example, on the 2019 Qin EV, the system triggers this fault when the high-voltage battery pack voltage exceeds approximately 420-450V or the compressor internal bus voltage reading exceeds the safe range.
This fault acts as a high-voltage safety protection mechanism for the thermal management system.
Upon detecting abnormally high voltage, the compressor actively disconnects the high-voltage relay to protect the IGBT power module and motor insulation.
Actual battery pack overvoltage, voltage sampling circuit drift, high-voltage interlock circuit faults, or control software logic errors can cause this fault.
Determine whether the condition is a genuine voltage abnormality or a signal detection fault.
Air Conditioning Failure After Fast Charging
Loose connection in compressor high-voltage harness triggered overvoltage protection
Voltage sampling circuit resistor aging
High regeneration during extended downhill driving caused momentary overvoltage