B110913

DTC B110913 indicates an open signal circuit for the PM2 — Qin Plus

Thermal Management System

DTC B110913 indicates an open signal circuit for the PM2.5 rapid detector (in-cabin air quality sensor).

This sensor typically mounts inside the air conditioning system intake duct.

It monitors in-cabin PM2.5 concentration in real time and provides data to the automatic air conditioning system for intelligent control of the air purification function.

The BYD diagnostic protocol uses sub-code '13' to specifically indicate an open signal circuit.

Although this fault theoretically affects a comfort feature, BYD Qin series vehicles classify it as a Level 3 (severe) fault.

This classification occurs because the air conditioning system interacts with the battery thermal management system (e.g., monitoring battery cooling intake air quality).

The fault can disable the automatic air conditioning mode and prevent the air purification function from operating.

In extreme cases, it affects the battery compartment intake air quality assessment, triggering the 'repair immediately' strategy.

4
Cases Logged
BYD DTC AI Analysis

Qin Pro EV sensor connector worked loose, causing intermittent fault codes

Started the car after overnight parking. Dash displayed "Air Conditioning System Fault". Scanned: DTC B110913. Inspected and found the PM2.5 sensor connector behind the passenger glovebox wasn't fully locked—it came loose with a light pull. Reconnected the connector and secured the harness with zip ties to relieve strain. Fault cleared. Root cause: Owner recently replaced the cabin air filter and accidentally bumped the sensor connector, leaving it not fully seated.
BYD DTC AI Analysis

Qin EV300 wiring harness chafing caused signal wire open circuit

When driving on rough roads, the AC panel showed abnormal readings. A scan tool retrieved stored DTC B110913. Teardown inspection found that prolonged vibration had damaged the sensor wiring harness insulation where it passes through the firewall metal sleeve. The signal wire's internal copper strands had broken while the outer jacket remained intact, causing an intermittent open circuit. Repaired the harness, added abrasion-resistant sleeving, and rerouted and secured the wiring away from sharp metal edges. Fault fully resolved.
BYD DTC AI Analysis

Qin Pro DM sensor body aging failure

This DTC appeared after 4 years of use. Checked power and ground circuits – both normal. Signal line continuity tested good. Measured infinite resistance at the sensor output terminal (spec: 1.5–2.5 kΩ), indicating the internal laser detection module had aged and failed open-circuit. Replaced with OEM PM2.5 sensor (part number BYDEG-8121400). After replacement, data stream showed normal PM2.5 values. Cleared the DTC and it has not returned.
BYD DTC AI Analysis

Qin EV300 wiring harness chafing caused signal wire open circuit

When driving on rough roads, the A/C panel showed erratic readings. The scan tool read stored fault code B110913. Disassembly inspection found the sensor wiring harness insulation damaged at the firewall metal grommet from prolonged vibration. The signal wire's internal copper strands were broken but the outer sheath remained intact, causing an intermittent open circuit. Repaired the harness, added abrasion-resistant sleeving, and rerouted and secured the harness to avoid contact with sharp metal edges. Fault completely resolved.
Data confidence: Community This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.