B2A0813

DTC B2A0813 indicates an open circuit in the air conditioning system evaporator outlet refrigerant temperature sensor (PT sensor) circuit — Qin Plus

Thermal Management System

DTC B2A0813 indicates an open circuit in the air conditioning system evaporator outlet refrigerant temperature sensor (PT sensor) circuit.

This sensor uses an NTC thermistor to monitor the evaporator outlet refrigerant temperature in real time (typical range -40°C to +85°C).

It provides critical temperature feedback to the HVAC ECU to precisely control the electronic expansion valve opening, compressor speed, and blower airflow, preventing evaporator surface icing and optimizing cooling efficiency.

The ECU logs an open circuit fault when it detects the sensor signal voltage continuously exceeding the threshold (typically above 4.95V, indicating an open circuit) for longer than a set time (e.g., 2 seconds).

This fault triggers the air conditioning system fail-safe mode, forcibly limiting compressor operation or completely stopping cooling, and may illuminate the relevant thermal management warning lamp.

Continuing to drive the vehicle may cause abnormal battery pack or motor heat dissipation, making this a severe fault.

5
Cases Logged
BYD DTC AI Analysis

Qin EV300 evaporator temperature sensor wiring harness chafed, open circuit

A 2017 Qin EV300 with 120,000 km showed "Air Conditioning System Fault" on the instrument cluster. A scan retrieved DTC B2A0813. Inspection found the evaporator outlet temperature sensor above the passenger-side evaporator box. Its harness had chafed against a metal bracket at the firewall, wearing through the insulation and completely severing the signal wire among the three cores. Fix: Cut out the damaged section, soldered the wires and insulated with heat-shrink tubing, re-secured the harness routing and added protective corrugated tubing. Cleared the code and the air conditioning returned to normal.
BYD DTC AI Analysis

Intermittent fault on new Yuan Plus from loose sensor connector

One week after delivery of a new 2023 Yuan Plus, the owner reported the air conditioning occasionally failed to cool, returning to normal after a restart. The scanner showed intermittent fault code B2A0813. Inspection found that although the evaporator outlet temperature sensor connector latched in place, the internal terminals hadn't fully engaged due to an assembly process issue, causing poor contact on rough roads. Fix: Reseated the connector with an audible 'click'. Monitored live data—no dropouts. Fault has not recurred.
BYD DTC AI Analysis

Tang DM sensor pins corroded open after water wading

A 2020 Tang DM suffered rainwater intrusion through a deteriorated front windscreen seal, allowing water into the dashboard interior and flooding the HVAC ECU and evaporator sensor connector. One week later the air conditioning failed with DTC B2A0813. Disassembly revealed severe green oxidation on the sensor male pins and loss of spring tension in the female terminals. Repair: Replaced the evaporator outlet temperature sensor assembly, cleaned the ECU-side connector with electronic contact cleaner, and replaced the firewall seal. Fault resolved.
BYD DTC AI Analysis

Aftermarket modification on Song Pro EV caused wiring harness to break under tension

While fitting ambient lighting to a 2019 BYD Song Pro EV at a third-party modification shop, the technician removed the passenger-side glove box and used the evaporator temperature sensor harness as an anchor point to secure the new lighting wiring. This over-tensioned the original sensor harness, fracturing the internal copper conductors while the insulation remained visually intact. The vehicle presented with complete loss of air conditioning cooling and active DTC B2A0813. Replaced the OEM harness (damage was too close to the root to allow effective soldering) and rerouted the wiring to prevent stress concentration.
BYD DTC AI Analysis

Han EV heat pump system sensor failure due to aging

2021 Han EV (heat pump A/C) showed poor winter heating and intermittent B2A0813 at 60,000 km. On this model, the evaporator outlet temperature sensor also monitors refrigerant status in heat pump mode. Testing found the sensor resistance drifted beyond spec below 5°C, showing open-circuit characteristics. Replaced with a new sensor model optimized for low temperatures. Heat pump system returned to normal and the fault code has not reappeared.
Data confidence: Community This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.