This DTC indicates the electric air conditioning compressor (E-Compressor) internal high-voltage drive circuit detected an abnormal overcurrent condition — Qin Plus
This DTC indicates the electric air conditioning compressor (E-Compressor) internal high-voltage drive circuit detected an abnormal overcurrent condition.
Specifically, the compressor's built-in permanent magnet synchronous motor (PMSM) drive current exceeded the IGBT power module safety threshold (typically 30-50A, depending on the vehicle model).
This fault involves the compressor internal high-voltage inverter module, motor winding insulation condition, or an abnormal mechanical load.
The compressor control unit (ECU) triggers this fault when it detects, via the Hall current sensor, that the instantaneous phase current continuously exceeds the calibrated threshold (e.g., 60A/100ms or 80A/10ms).
This fault initiates an automatic compressor protective shutdown, affecting air conditioning cooling and battery thermal management functions.
In extreme cases, it may damage the high-voltage fuse or high-voltage wiring harness.
2019 Qin Pro EV: Air conditioning suddenly stopped working while driving
Batch failure of A/C compressor IGBT modules in new Yuan Plus vehicles
Refrigerant leak caused compressor overcurrent in BYD Qin EV300
Qin Pro DM compressor control board current sampling abnormality