DTC C057A00 indicates an abnormally high voltage or a short to power (B+) in the IPB (Intelligent Power Brake) internal brake booster temperature sensor power supply circuit — Qin Plus
DTC C057A00 indicates an abnormally high voltage or a short to power (B+) in the IPB (Intelligent Power Brake) internal brake booster temperature sensor power supply circuit.
Integrated within the electronic brake booster, this sensor monitors the operating temperature of the booster motor or electronic control unit in real time to prevent brake performance degradation or motor burnout from overheating.
The IPB-ECU logs a power supply short circuit fault when the sensor supply line (typically a 5V reference voltage) continuously exceeds the calibrated threshold (generally above 6.0V or reaching the 12V battery voltage).
This fault triggers the IPB system safety protection mechanism.
It may limit or completely disable brake assist, degrade ABS/ESP functions, and force the vehicle into Limp Home Mode.
The system retains only basic unassisted hydraulic braking.
This constitutes a severe fault affecting driving safety.
Song PLUS DM-i firewall wiring harness chafing caused short to power
BYD Seal IPB temperature sensor seal failure, internal short circuit
BYD Dolphin IPB sensor connector water ingress and corrosion
Han DM-i IPB module internal reference voltage abnormal
BYD Song Pro DM-i wiring error after accident repair