B2AB81C

This DTC indicates abnormal three-phase inverter voltage in the electric A/C compressor (electric scroll compressor) drive system — Seal 6 EV

Thermal Management System

This DTC indicates abnormal three-phase inverter voltage in the electric A/C compressor (electric scroll compressor) drive system.

Specifically, the Intelligent Power Module (IPM) driving the compressor's built-in Permanent Magnet Synchronous Motor (PMSM) detects the equivalent voltage of any U/V/W phase exceeding the safety threshold (typically >650V DC peak voltage after PWM modulation).

This fault triggers a protective compressor shutdown, disabling the A/C system.

It may also derate the vehicle thermal management system, affecting power battery cooling and heating functions.

Fundamentally, this indicates a high-voltage drive circuit or voltage sampling circuit fault.

Determine whether the condition is a true overvoltage (high-voltage bus fault) or a false overvoltage (sensor drift).

5
Cases Logged
BYD DTC AI Analysis

Qin EV Air Conditioning Failure After Fast Charging

After charging with a 120kW fast charger from a particular brand, the dashboard displayed "Air Conditioning System Fault". DTC B2AB81C. Freeze frame showed the bus voltage reached 738V when the fault occurred (normal maximum 680V). Found the fast charger output voltage had drifted. BMS overvoltage protection activated late, causing the compressor controller to trigger phase voltage protection. Fault cleared after switching to a different fast charger. Advised the customer to avoid this brand of charging station.
BYD DTC AI Analysis

Compressor controller sampling circuit fault

Air conditioning suddenly stopped working while driving; no collision history. Scanner read DTC B2AB81C. Live data showed the compressor phase voltage jumping between 0–800 V while the actual bus voltage held stable at 650 V. Disassembled the compressor controller (IPM) and found a cold solder joint on voltage divider resistor R15 (100 kΩ) causing sampling drift. Resoldered the resistor and applied conformal coating. Fault resolved.
BYD DTC AI Analysis

Three-phase harness insulation failure from wear.

After flood damage repairs (flood depth ~40 cm), the air conditioning intermittently failed to cool, setting DTC B2AB81C. Inspection found the compressor three-phase high-voltage harness chafed at the front cabin firewall penetration; damaged insulation caused high-voltage leakage to chassis (insulation resistance only 2 MΩ). Replaced the compressor harness assembly and resealed to IP67. The fault has not recurred.
BYD DTC AI Analysis

Improper software calibration caused false positive

2019 Qin EV triggered DTC B2AB81C, commonly during rapid acceleration followed by immediate AC activation. Technical bulletins indicate early software used an overly conservative phase voltage OVP threshold of 620V. The updated software raises this to 680V and optimizes voltage filtering. Reflashed the ACU to V2.3.5; fault eliminated.
BYD DTC AI Analysis

Compressor motor winding insulation deterioration

A Qin EV taxi with 180,000 km exhibited gradually deteriorating air conditioning cooling performance until complete failure, logging DTC B2AB81C. Insulation resistance between the compressor three-phase lines and housing measured 15 MΩ, 8 MΩ, and 0.5 MΩ respectively (severely uneven). Disassembly revealed aged, flaking motor winding insulation varnish with localized breakdown to the housing. Replaced the electric compressor assembly and recovered the old unit for motor teardown analysis, confirming insulation deterioration from prolonged high-load operation.
Data confidence: Community This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.